- Agency
-
Accessories
-
Waterfall
- Aeration
-
Power
-
Thermal blinds
- PROMOTIONS
-
Air conditioning Heating
-
Kitchen
- Kitchen hoods
- Cooking
- Kitchen accessories
- Kitchen sinks
-
Refrigerators
- Fridge fans
- Dometic Trivalent Fridge
- Dometic Fridge Compressor
- INDELB refrigerators
- Thetford Tr / Comp fridge
- VITRIFRIGO refrigerators
- Aerators for refrigerators
-
Spare parts for refrigerators
- Fridge lighters
- Spare parts for Dometic refrigerators and grills
- Fridge nozzle burners
- Ignition candles fridge
- Fridge hinges
- Refrigerator closures
- Various for fridge
- Interrutt Selett fridge
- Knobs Fridge handles
- Fridge masks
- Shelves for Dometic fridge
- Resistors for fridge
- Fridge panels cards
- Fridge thermostats
- Refrigerator thermocouples
- Gas valves for refrigerators
- FRIGORIFERI A COMPRESSORE MESTIC
- Drains and siphons 1
-
Electricity
-
Cell exteriors
- Luggage box
- Locker door hinges
- Compressors
- Lockers and garages
- Steps
- Squeegee cleaning brushes
- Climbing and towing handles
- Bumpers
- Walls and blockers
-
External bike racks
- External gas bottle holders
- External motorcycle racks
- Roof rack
- East doors and mosquito nets
- Profiles and gaskets
- Rain protection DRIP STOP
- Remove black lines
- External ladders
- Folding roof
-
Verandas
-
Lighting
- Reflectors
- Post lights. trailers
- Auxiliary lights
- Decorative finishes
- Direction indicators
- Automotive bulbs
- Front clearance lights
- Side marker lights
- Rear clearance lights.
- Plate lights
- Front single modules
- Individual post forms
- Multifunction post. complete
- Multif. post. composib.
- Third stop
- Various lights
-
Gas
-
Lighting
-
Cell interior
- Mattresses and beds
-
Multimedia
-
Do it yourself workshop
- Outdoor
- External sockets and spare parts
-
Safety
-
Toilet
-
Vehicle
- External screen printing
- Car body
- Curtain carpet
-
External locks
- Varie
- OUTLET
-
Waterfall
- Spare parts
AUTOMATIC SHUTTER APPROVED FOR CAMPER LPG CYLINDERS 30MB - 1.5KG - CAVAGNA
Rif: 13064
CAVAGNA - Automatic reverser for 2 LPG cylinders with 30mb regulator, flow rate 1.5Kg/h
EN16129 ANNEX D STANDARD FOR RECREATIONAL VEHICLES
The regulator - exchanger is specially designed to power a gas system on a caravan, camper or fresh water boat, as per the specifications of Annex D of the EN16129 standard. The product automatically switches a two-cylinder gas system to the reserve cylinder when the service cylinder is used up.
The knob changes from green to red when the cylinder is empty.
TECHNICAL INFORMATION
- Butane / Propane
- Flow rate: 1.5 kg/h
- Calibration: 30 mbar
- Entrances: M 20x1.5
- Outlet: with Copper/Steel tube nose cone Ø 8 mm
- Standard: EN16129
- Operating temperature: -20/+50°C
INPUTS:
It connects with 2 GOK or TRUMA hoses with M20X1.5 gas regulator thread. See high pressure hoses category.
If you wish to transform the M 20x1.5 male gas inlets for gas regulators into male connections for W 20 x 1/14 SX Italian cylinders, use two adapters, our code 15805.
EXIT:
Outlet with ogive fitting for connection to 8mm copper or steel pipe.
Compatible with Truma Gas Filters.
- Inlet pressure: 0.7-16 bar
- Regulated pressure: 30 mbar
- Guaranteed output: 1.5 Kg/h
- INPUTS G.13-G.14-G.18-G.23 of EN16129
- OUTPUT: H.7-Hp-H.11-H.19 of EN16129
Extract from the use and maintenance manual
.......
PUTTING “SERVICE” INTO USE
After checking that the indicator remains green in both positions of the knob, rotate the knob so that the arrow points to the right or left. The arrow on the knob will indicate the cylinder in "service" use.
OPERATION OF THE “RESERVE”
The indicator is red, which means the “in service” cylinder has been used up. It is now empty and the installation works on the "reserve" cylinder.
REPLACEMENT OF THE “EMPTY” CYLINDER
Rotate the knob half a turn. The cylinder previously in "reserve" becomes the cylinder in "service", the indicator normally turns green. If it remains red it means that the installation has worked too hard with the cylinder in "reserve" and the latter is also empty. It will therefore be necessary to change both cylinders.
- Close the tap on the empty cylinder. Disconnect the cylinder.
- Connect the full cylinder. Check that the connections are closed correctly and that there are no leaks using a foaming product.
- When the operator check is finished, reposition the arrow on the cylinder previously in use in order to empty it. The new cylinder now constitutes the "reserve" of the installation.
...........
Operating temperature range: -20°C + 50°C
...
It cannot be used in closed rooms as it has an overpressure (vent) device which discharges into the atmosphere when the gas pressure exceeds the set value.
......
You will immediately get a €10 discount
Shipping starting from € 8.90 up to 2 kg and not bulky (sum three sides not exceeding one meter)
Shipping from €22.00 up to 2 kg and not bulky (sum 3 sides over a meter). Superiors ask quote.
Orders minimum £135, excluding shipping. Customs duties and taxes are the customer's responsibility.
You might also like
-
Frequently purchased together
11 other products in the same category:
Gas regulator TRUMA MONOCONTROL CS 30mbar with crash sensor 8/10 after 2019 -...
Rif: 12561
- -€10.00
Vertical gas regulator DUOCONTROL CS 30mbar with crash sensor 8/10 after 2019...
Rif: 12560
- -€20.00
Gas regulator HORIZONTAL DUOCONTROL CS 30mbar with crash sensor 8/10 after...
Rif: 12559
- -€20.00