Rif: 13064
The regulator - exchanger is specially designed to power a gas system on a caravan, camper or fresh water boat, as per the specifications of Annex D of the EN16129 standard. The product automatically switches a two-cylinder gas system to the reserve cylinder when the service cylinder is used up.
The knob changes from green to red when the cylinder is empty.
TECHNICAL INFORMATION
INPUTS:
It connects with 2 GOK or TRUMA hoses with M20X1.5 gas regulator thread. See high pressure hoses category.
If you wish to transform the M 20x1.5 male gas inlets for gas regulators into male connections for W 20 x 1/14 SX Italian cylinders, use two adapters, our code 15805.
EXIT:
Outlet with ogive fitting for connection to 8mm copper or steel pipe.
Compatible with Truma Gas Filters.
Extract from the use and maintenance manual
.......
PUTTING “SERVICE” INTO USE
After checking that the indicator remains green in both positions of the knob, rotate the knob so that the arrow points to the right or left. The arrow on the knob will indicate the cylinder in "service" use.
OPERATION OF THE “RESERVE”
The indicator is red, which means the “in service” cylinder has been used up. It is now empty and the installation works on the "reserve" cylinder.
REPLACEMENT OF THE “EMPTY” CYLINDER
Rotate the knob half a turn. The cylinder previously in "reserve" becomes the cylinder in "service", the indicator normally turns green. If it remains red it means that the installation has worked too hard with the cylinder in "reserve" and the latter is also empty. It will therefore be necessary to change both cylinders.
...........
Operating temperature range: -20°C + 50°C
...
It cannot be used in closed rooms as it has an overpressure (vent) device which discharges into the atmosphere when the gas pressure exceeds the set value.
......
You will immediately get a €10 discount
Shipping starting from € 8.90 up to 2 kg and not bulky (sum three sides not exceeding one meter)
Shipping from €22.00 up to 2 kg and not bulky (sum 3 sides over a meter). Superiors ask quote.
Orders minimum £135, excluding shipping. Customs duties and taxes are the customer's responsibility.
You might also like
Rif: 12561
Rif: 12560
Rif: 12559
The regulator - exchanger is specially designed to power a gas system on a caravan, camper or fresh water boat, as per the specifications of Annex D of the EN16129 standard. The product automatically switches a two-cylinder gas system to the reserve cylinder when the service cylinder is used up.
The knob changes from green to red when the cylinder is empty.
TECHNICAL INFORMATION
INPUTS:
It connects with 2 GOK or TRUMA hoses with M20X1.5 gas regulator thread. See high pressure hoses category.
If you wish to transform the M 20x1.5 male gas inlets for gas regulators into male connections for W 20 x 1/14 SX Italian cylinders, use two adapters, our code 15805.
EXIT:
Outlet with ogive fitting for connection to 8mm copper or steel pipe.
Compatible with Truma Gas Filters.
Extract from the use and maintenance manual
.......
PUTTING “SERVICE” INTO USE
After checking that the indicator remains green in both positions of the knob, rotate the knob so that the arrow points to the right or left. The arrow on the knob will indicate the cylinder in "service" use.
OPERATION OF THE “RESERVE”
The indicator is red, which means the “in service” cylinder has been used up. It is now empty and the installation works on the "reserve" cylinder.
REPLACEMENT OF THE “EMPTY” CYLINDER
Rotate the knob half a turn. The cylinder previously in "reserve" becomes the cylinder in "service", the indicator normally turns green. If it remains red it means that the installation has worked too hard with the cylinder in "reserve" and the latter is also empty. It will therefore be necessary to change both cylinders.
...........
Operating temperature range: -20°C + 50°C
...
It cannot be used in closed rooms as it has an overpressure (vent) device which discharges into the atmosphere when the gas pressure exceeds the set value.
......